Why Won't My Spa Heat Up? In-Ground Spa Heating Problems and Fixes

November 15, 2026

Last updated:

Raised tiled spa spilling into a rectangular pool with a stone deck beside a lake

Most in-ground spas that won't heat have a setting or valve problem, not a broken heater. Check that spa mode is on, the set point is above the water temperature, and both valves turned. Still cold? Call Lucent Pools: 817-339-6770.

Why is my pool heating but not my spa?

Usually a valve didn't turn all the way to the spa, so the heater is warming pool water instead. In spa mode, the system turns two valves, one on the suction side and one on the return, so only spa water runs through the heater.

Pentair's EasyTouch guide describes it this way: spa mode turns the valves so the filter pump circulates only spa water, and the pump switches off for a moment while the valves rotate. If a valve actuator fails, the panel can still show spa mode while pool water keeps running through the heater. The pool gets a little warmer and the spa doesn't.

Signs it's a valve:

  • The spa water level drops or overflows into the pool while you're in spa mode. Jandy's valve actuator manual lists spa draining or overflowing as the sign that an actuator runs but its valve doesn't turn.
  • The spa jets are weak, or water still pours over the spillway when the spa should be running on its own.
  • The pool is warming up and the spa isn't.

Switch to spa mode, give the valves about half a minute, and look at the equipment pad to see whether both actuators moved. If one didn't, leave the valves as they are and call. Valve actuators and the automation that drives them are a repair. See pool automation repair.

Is my spa actually set to heat?

Check three settings first: spa mode is on, the spa set point is higher than the water temperature, and the heat source isn't set to Off. Most systems keep the spa's heat setting separate from the pool's, so the pool can be set to heat while the spa isn't.

  • Set point: Hayward's heater troubleshooting steps start with the filter pump on, the heater enabled, and the set point higher than the current water temperature.
  • Heat source: On Pentair IntelliCenter, the spa pump has to be on to activate the heater, and you pick a heat source with the Heat Mode button. A heat mode of Off means no heat source.
  • Pool or spa on the heater: A heater like Pentair's MasterTemp lets you choose between pool and spa heating, each with its own set point. If it's left on pool, the spa only heats to the pool setting.
  • Schedules: A timer or automation schedule can switch the system back to pool mode while you're waiting for the spa.
  • Spillover: Heating in spa-only mode is faster than running the spillover, because spillover sends warm spa water into the pool.

Your automation's owner's manual shows where each setting lives.

Why does my heater say "heating" but the spa stays cold?

That usually means the heater isn't getting power, water flow, or a clean signal from the controller, or it has shut itself off with a fault. Read the heater's own display before anything else.

Hayward lists these reasons a heater shows "Heating" but doesn't run: the cable between the heater and the controller is unplugged or damaged, the heater has no power, or the heater has found a problem and shows an error code. Hayward names IF (ignition failure), LO (a pressure switch problem) and AO (a vacuum switch problem) as common ones.

What you can check:

  • The breaker for the heater is on. If it trips again, leave it off and call.
  • Water flow: the pump is running, and the pump basket and filter are clean. Gas heaters have a water pressure switch that keeps them off when flow is low.
  • The code: look it up in our guides for Jandy, Pentair, Hayward and Raypak heaters.

Don't open the heater or touch its gas valve. We repair and replace gas and propane pool heaters. Gas line work, including new runs and changes to existing lines, is done by our licensed gas contractor, with permits where required. See pool heater repair.

Why won't my spa heat when it's cold or freezing outside?

Freeze protection and cold air can both get in the way. Some automation systems won't run the heater while freeze protection is running in pool mode, and heat pumps slow down or stop on very cold days.

Hayward says the heater can't run while freeze protection is on and the system is in pool mode, that freeze protection can be overridden to heat in spa mode only, and that a bad air temperature sensor can put the system in freeze protection by mistake. Pentair IntelliCenter has a Spa Freeze Override Time that runs the pump and heats the spa during freezing temperatures. Your automation's manual shows how to use the override on your system.

If you heat with a heat pump, a slow heat-up in a cold snap isn't always a breakdown. More on why heat pumps stop heating. Before a hard freeze, see how to get your pool ready for a hard freeze.

How long should an in-ground spa take to heat up?

It depends on the heater's size, the spa's size, how cold the water starts, and the weather. There's no single number, so compare it with how your spa heated last winter in similar weather.

If it now takes much longer than it used to, look at the usual suspects in order: spa-only mode, both valves turned, a clean filter and good flow, then the heater itself. A spa that warms a little and then stalls often points to a valve letting pool water in, or a heater shutting off on a fault.

Is my spa losing water when I heat it?

If the spa level drops or overflows into the pool only while you're in spa mode, one valve probably turned and the other didn't. That usually points to a valve or actuator problem, not a leak.

If the spa level drops even with the equipment off, that points to a possible leak. We find and fix pool leaks. See pool leak detection and repair.

When should I call a pro for a spa that won't heat?

Call when the settings are right and it still won't heat, a valve won't turn, the heater shows a code, or a breaker trips again.

You can checkCall a pro
Spa mode on, spa set point above the water temperature, heat source not OffSettings are right and the spa still won't heat
Both valve actuators moved after switching to spaAn actuator doesn't move, or the spa drains or overflows in spa mode
Heater breaker on; pump basket and filter cleanBreaker trips again, or the heater shows an error code
Freeze protection override on your automationAir temperature on the panel looks wrong, or freeze protection won't let go

We service and repair all pool equipment brands, including Jandy, Pentair, and Hayward. We are an Authorized Jandy ProEdge Warranty Station and can also help with Pentair and Hayward warranty claims. We repair in-ground pools and in-ground spas. We do not repair portable hot tubs. Lucent Pools is insured.

Next step

Spa still won't heat? Call 817-339-6770, Monday through Friday, 8:00 AM to 6:00 PM. Saturday closed. Sunday closed. We repair pool heaters in Fort Worth, Frisco, Lewisville, and most of the DFW Metroplex, often same day or next day when parts and schedule allow. After we diagnose it, we send you an estimate and call to walk you through it. Our standard rates are on the pool repairs page.

More help: pool repair in Fort Worth and Dallas–Fort Worth, pool repair in Keller, pool repair in Southlake.

Need a Repair?

Call Lucent Pools at 817-339-6770. We diagnose on site in Fort Worth, Frisco, Lewisville, and most of the DFW Metroplex. Same day or next day when parts and schedule allow.

Frequently Asked Questions

Why is my pool warm but my spa cold?

Usually a valve didn't turn to the spa, so the heater is warming pool water instead. Switch to spa mode and watch both valve actuators at the equipment pad. If one doesn't move, or the spa level drops or overflows, call 817-339-6770.

Why won't my spa heater turn on?

Check that spa mode is on, the spa set point is above the water temperature, the heat source isn't set to Off, and the filter pump is running. Then check the heater's breaker and display. An error code, or a breaker that trips again, needs a technician.

Can I heat my spa while freeze protection is on?

Often, yes, but some systems block the heater while freeze protection runs in pool mode. Hayward says freeze protection can be overridden to heat in spa mode, and Pentair IntelliCenter has a spa freeze override. Your automation's manual shows how. A bad air sensor can also cause it.

How long should it take to heat an in-ground spa?

It depends on the heater's size, the spa's size, how cold the water starts, and the weather. Heat pumps slow down on very cold days. If your spa now takes much longer than it used to in similar weather, have the valves, flow and heater checked.

Do you repair heaters and valves on in-ground spas?

Yes. We repair in-ground pools and in-ground spas, including heaters, heat pumps, valves and automation. We service and repair all pool equipment brands, including Jandy, Pentair, and Hayward. We do not repair portable hot tubs. Call 817-339-6770 to book a diagnosis.