Most Pentair alarms on a pump, heater, automation panel or salt cell trace back to water flow, power or a sensor. Some you can check yourself. Lucent Pools diagnoses and repairs Pentair equipment on in-ground pools across DFW. Call 817-339-6770.
Based in Dallas–Fort Worth, serving Fort Worth, Frisco, Lewisville, and most of the DFW Metroplex.
We repair Pentair pool equipment in Fort Worth, Frisco, Lewisville, and most of the DFW Metroplex.
We repair in-ground pools and in-ground spas. We do not repair portable hot tubs.
We service and repair all pool equipment brands, including Jandy, Pentair, and Hayward. We can help arrange Pentair and Hayward warranty claims.
Turn the equipment off at the circuit breaker before you open a pump lid or reach into any equipment. Pentair says to disconnect power at the circuit breaker and relieve pressure in the filter system before servicing a pump, and not to adjust or service it without consulting a qualified pool technician. Never run a pump without water. Don't open a heater, heat pump, automation panel or salt power center; Pentair warns of electric shock inside. If a breaker trips again after one reset, leave it off and call. If you smell gas, don't light any appliance and don't touch electrical switches or use a phone in the building. Call your gas supplier from a neighbor's phone, or the fire department if you can't reach them. Never open the gas valve, burner or any gas part yourself. Don't use any equipment that has been under water.
How do I diagnose a Pentair pool pump alarm? (IntelliFlo / variable speed)
A Pentair variable-speed pump stops or slows itself when it senses a problem and shows an alarm on the pump, the app or the automation panel. Priming alarms usually mean air or low water; overheat alarms usually mean blocked cooling or a hot day. Note the exact alarm, then check the water level and baskets.
On an IntelliFlo3 VSF or IntelliPro3 VSF, a red blinking ON/STOP light is an alarm and the pump stops until it's resolved. A green or yellow blinking light is a warning and the pump keeps running (P/N 356231 Rev F, p. 20 and p. 23). The alarms and warnings are Priming Failure, Overheat, Over Current, Over Voltage, Under Voltage, Internal Fault, Drive is Derating, Derating Alarm – Exceeded & Cut Off, Thermal Mode, Speed, Pressure, and Flow Limit warnings, and Offline or Weak WiFi (p. 23). The IntelliFlo3 VSF User's Guide P/N 356088 Rev C lists the same alarms.
On an older IntelliFlo VSF, the alarm light is on the keypad and the buttons stay disabled until the alarm is cleared. Those alarms and warnings are Power Out/OFF, Priming Failure (five failed attempts is a permanent alarm), Overheat (the drive is above 130°F and the pump slows), Over Current, Over Voltage, Internal Error, and Speed, Pressure, and Flow Limit warnings (P/N 356652 Rev F, p. 25).
On IntelliCenter the pump messages are Priming Alarm, Drive Over Temperature or Drive Temperature, Over Current, Over Voltage, Power Outage, and Communication Lost (P/N 522990 Rev F, pp. 117–118).
Turn the power off at the breaker before you open anything. For a priming alarm, keep the water high enough that the skimmer isn't drawing air, empty the skimmer and pump baskets, and seat the lid with its O-ring clean (P/N 356231 Rev F, p. 21; P/N 356652 Rev F, p. 26). Clean the lid O-ring only. For Overheat or drive temperature, keep the back of the pump and the fan area clear of leaves and dirt. For Over Voltage or Under Voltage, Pentair says the alert clears and the pump resumes when supply voltage returns to range (P/N 356231 Rev F, p. 23). Do nothing inside the pump. If it repeats, call. For Internal Fault, Pentair says a power cycle may clear it. If it comes back, we handle it. For Offline or Weak WiFi, check that the home router is on and online.
Call if an alarm returns after those checks, for any Over Current (Pentair's fix is disassembling the pump to clear the impeller, which is technician work), if an Internal Fault comes back, if a breaker trips again, if water leaks from under the motor (Pentair calls that a worn shaft seal, a wear part), or if the pump won't run with power on.
We test the electrical side first, repair what failed, and replace the motor only if needed. For a pump that won't start, hums, leaks, or is noisy, see pool pump problems. See pool pump repair.
How do I diagnose a Pentair pool heater or heat pump? (MasterTemp, Max-E-Therm, UltraTemp)
Most Pentair heater and heat pump faults start with water flow: the pump is off, the filter is dirty or a valve is closed. Gas heaters show short codes like ERR PS or ERR IGN; UltraTemp heat pumps show full-word alarms like LOW WATER FLOW. Check the pump and filter first.
Gas heaters: MasterTemp and Max-E-Therm
ERR PS: The heater's water pressure switch isn't sensing enough water flow, so it won't fire. ERR IGN: The ignition control module tried to light the burner and couldn't. Make sure other gas appliances work and the propane tank isn't empty. Don't turn gas valves or open the heater; call us or your gas company.
The Service System light means restricted flow. MasterTemp guide P/N 472592 Rev Q, pp. 44–45, lists these codes. We repair and replace gas and propane pool heaters. Gas line work, including new runs and changes to existing lines, is done by our licensed gas contractor, with permits where required. Full code list: Pentair heater error codes.
Heat pumps: UltraTemp
LOW WATER FLOW means the water pressure switch is open: the pump is not on, the filter is dirty, traps are clogged, an external bypass is open, or the switch is bad. HIGH REFRIG means the high-pressure switch is open. Pentair lists low water flow or a bypass left open, and also switch or valve faults. Call a technician for those. LOW REFRIG means the low-pressure switch is open: the air and water are too cold to run, airflow is blocked, the fan has a fault, or refrigerant is low. Call a technician. These are Pentair's alarm names and listed causes.
LOW AMBIENT TEMP or ice on the coil means defrost didn't finish or the air is too cold. HIGH WATER TEMP, LOW WATER TEMP, or WATER THERM OPEN or SHORT points to a thermistor or the control board. FIVE ALARMS means five faults in one hour. Pentair says it resets itself after an hour, and the alarm that caused it is the one to watch (P/N 474099 Rev AA, p. 29). A blank display that won't start can be no power, a tripped breaker, a blown fuse, a transformer, or wiring. The same alarms can show on IntelliCenter. These meanings are from the UltraTemp guide, P/N 474099 Rev AA, pp. 27–29.
Check that the pump is running, the filter and baskets are clean, and the valves are open. Keep leaves, shrubs, and debris clear of the unit, and make sure sprinklers don't spray it. Heat pumps slow down or stop on very cold days, so a slow heat pump in a cold snap is not always broken. If ice forms, shut the heat pump off and let it thaw. For a blank display, check the breaker once. See pool filter problems.
Call when LOW WATER FLOW or HIGH REFRIG stays with the pump running and a clean filter, when LOW REFRIG happens in mild weather or ice keeps forming, for any sensor or thermistor alarm, if a breaker trips again, or for anything inside the cabinet.
We check flow, gas or power, and the heater itself, then tell you whether repair or replacement is the better call. When one stops heating we check the fan, the compressor, the sensors, and the airflow around the unit. See pool heater repair and pool heat pump repair.
How do I diagnose a Pentair automation system? (EasyTouch, IntelliCenter, ScreenLogic)
When Pentair automation stops running schedules, first check whether the panel was left in Service or Timeout mode or lost its clock after a power outage. "Communication Lost" usually means a cable between the panel and a pump, heater or salt cell. App problems are usually the home network or the ScreenLogic adapter.
EasyTouch shows SERVICE or TIMEOUT on the panel. Schedules and remotes are disabled in Service. Timeout returns to AUTO by itself after three hours (EasyTouch User's Guide P/N 521044 Rev C, p. 4). After a power failure the Egg Timer won't switch a circuit back on (p. 12). Air Err and an Air, Water, or Solar Temperature Err mean a sensor is not connected or is defective (p. 61). An indoor panel that is blank, or lit but won't run equipment, points to the cable between the indoor and outdoor panels (p. 63). Chlorinator menu messages include COM LINK ERROR, CHECK FLOW/PCB, LOW SALT, VERY LOW SALT, HIGH CURRENT, CLEAN CELL!!, and LOW VOLTAGE (p. 62).
IntelliCenter shows SERVICE MODE on the outdoor panel, the indoor panel, and a remote. All auxiliary circuits stay disabled in Service or Timer mode until AUTO is selected (IntelliCenter User's Guide P/N 522990 Rev F, p. 37). Communication Lost for a pump, heater, IntelliChem, or salt cell means the cable or RS-485 connection (pp. 111, 115, 116, and 117).
With ScreenLogic2 you can't log in to the app, or you are logged in but the equipment won't respond (ScreenLogic2 Interface Troubleshooting Guide, 2024; ScreenLogic2 guide P/N 520493 Rev M, p. 67).
If the panel shows SERVICE or TIMEOUT, schedules won't run. Put the panel back in AUTO (EasyTouch User's Guide P/N 521044 Rev C, p. 4; IntelliCenter User's Guide P/N 522990 Rev F, p. 37). Wrong schedules often mean a panel that lost its clock after a power cut, a mis-set program, or a sensor feeding bad data. For ScreenLogic2, check the red power light on the protocol adapter, that the ethernet cable is seated in the router, that the 6-digit login is correct (no letter O, only zero), that the indoor wireless antenna is at least one to two feet from the Wi‑Fi router, and that the Rx/Tx lights are flickering. Don't open the load center or outdoor panel.
Call when Communication Lost stays, for any sensor error, for a blank or frozen panel, if the panel won't hold the clock, if equipment won't respond from the panel itself, or for outdoor antenna wiring. Pentair says to contact your local pool professional to inspect the wiring of your outdoor antenna.
We diagnose panels, apps, timers, and actuators on site, then repair or replace so schedules and valves run again. We diagnose on the existing circuits only. We repair anything electrical on your pool, from pumps, heaters, and automation to timers, salt systems, and pool lights, and connect or disconnect it on your existing circuits. See pool automation repair.
How do I diagnose a Pentair salt cell? (IntelliChlor)
IntelliChlor uses status lights to tell you why it isn't making chlorine. A red COLD WATER light is normal in winter: the cell stops below about 52°F. A red FLOW light means not enough water is reaching the cell, and a flashing green CELL light usually means scale.
COLD WATER red means standby and no chlorine, with water below 52°F (11°C). It resumes, with accurate salt readings, above 52°F (IntelliChlor guide P/N 520589 Rev R, p. 7 and p. 20). IntelliCenter says that when the water is this cold, you should manually add chlorine to your pool, if needed (P/N 522990 Rev F, p. 117). FLOW red means not enough flow through the cell, so it makes no chlorine (p. 7). Causes are a pump that lost prime or clogged strainer baskets, closed valves, a dirty filter, or an obstruction in the cell (p. 29).
CELL flashing green means the cell needs inspection. The blades may have calcium buildup, and it is not producing chlorine (p. 7 and p. 29). On automation that shows as CLEAN CELL!! or Clean & Inspect Cell. A red salt light means low or very low salt, and very low means the cell is off. A flashing green salt light means the salt is too high (p. 7). After adding salt, run the pump at least 24 hours before reading salinity (p. 7). No lights means no power: a fuse in the power center, no AC from the timer, or wiring (p. 29).
Keep the pump running and primed, the baskets and filter clean, and the valves open. In cold water, nothing is broken. Keep chlorine up by hand if needed. Have the salt level tested, and give it 24 hours after adding salt. Confirm the timer or automation is running the pump. A pump running too slow can trip a salt system's no-flow light.
Call if FLOW stays red with the pump running and a clean filter, if CELL keeps flashing after the salt tests fine (a false low-salt reading can mean a scaled or worn cell or a bad sensor), if the unit has no lights with the pump running, or if COLD WATER stays red once the water is clearly above 52°F.
We test the salt cell, salt level, flow switch, and power center, then repair or replace so chlorine output is steady. If the salt really is low, the fix is adding salt, not a new cell. See pool salt system repair.
What can I check myself, and when should I call?
You can safely check power at the breaker, the schedule, the water level, the baskets, the filter, the valves and the status lights. Anything inside a motor, heater, heat pump, panel or power center, and any alarm that comes back after those checks, needs a technician.
| Equipment | Alarm or symptom (as Pentair shows it) | Likely cause (per Pentair) | Safe to check yourself (power off first) | Call us when |
|---|---|---|---|---|
| IntelliFlo pump | Priming Failure / Priming Alarm / PRIME ERROR | Air leak on the suction side, low water, clogged basket | Water level, skimmer and pump baskets, lid seated | The alarm comes back after those checks |
| IntelliFlo pump | Overheat / Drive Over Temperature / Drive is Derating | Blocked cooling fan or very hot air | Clear leaves and dirt from the back of the pump | It keeps slowing down or shutting off |
| IntelliFlo pump | Over Current | Debris or worn parts loading the motor, or supply voltage | Nothing inside the pump | Every time it repeats (impeller check is technician work) |
| IntelliFlo pump | Over Voltage / Under Voltage / Power Out | Supply voltage out of range | Wait for it to clear on its own | It doesn't clear, or keeps coming back |
| IntelliFlo pump | Internal Fault / Internal Error | Drive hardware or software error | Note the alarm | It comes back after a power cycle |
| IntelliFlo pump | Water under the motor | Worn shaft seal | Note where the water comes from | Always |
| MasterTemp / Max-E-Therm | ERR PS, Service System light | Low water flow | Pump running, filter and baskets clean, valves open | ERR PS stays after those checks |
| MasterTemp / Max-E-Therm | ERR IGN / Ignition Lockout | Gas supply, igniter, ignition module or gas valve | Other gas appliances work, propane tank not empty | It comes back (see Pentair heater error codes) |
| UltraTemp heat pump | LOW WATER FLOW | Pump off, dirty filter, bypass open, bad pressure switch | Pump running, filter and baskets clean, valves open | It stays with the pump running |
| UltraTemp heat pump | HIGH REFRIG | Usually low water flow; switch or valve fault | Same flow checks | It stays after the flow checks |
| UltraTemp heat pump | LOW REFRIG / LOW AMBIENT TEMP / ice on the coil | Too cold to run, blocked airflow, fan, low refrigerant | Clear plants and debris; keep sprinklers off it; let ice thaw with it off | It happens in mild weather or keeps icing |
| UltraTemp heat pump | Water temp or WATER THERM alarms; FIVE ALARMS | Sensor or control board; repeated faults | Note which alarm caused it | Any sensor alarm, or FIVE ALARMS returns |
| EasyTouch / IntelliCenter | Schedules not running; panel shows SERVICE or TIMEOUT | Panel left in manual mode | Check the panel's mode; check clock after an outage | Schedules still don't run in AUTO |
| EasyTouch / IntelliCenter | Communication Lost (pump, heater, salt cell) | Cable between the device and the panel | Don't open the panel | Always |
| EasyTouch | Air Err / Water Temperature Err | Sensor unplugged or failed | Nothing | Always |
| EasyTouch / IntelliCenter | Panel blank or won't run equipment | Panel cable, power supply or board | Breaker once | It stays blank or trips again |
| ScreenLogic | App won't connect or equipment won't respond | Adapter power, network cable, login, antenna placement | Adapter power light, ethernet cable, 6-digit login, antenna a foot or two from the router | Rx/Tx lights still don't flicker |
| IntelliChlor | COLD WATER red | Water below about 52°F; cell on standby | Nothing; add chlorine by hand if needed | It stays red in warm water |
| IntelliChlor | FLOW red | Low flow: lost prime, closed valve, dirty filter, blocked cell | Pump primed, baskets, filter, valves | It stays red with good flow |
| IntelliChlor | CELL flashing green / CLEAN CELL | Calcium scale on the blades | Have the salt level tested | Every time (cleaning and output test) |
| IntelliChlor | Salt light red | Low salt (rain, leak) or a scaled cell or sensor | Have the salt tested; wait 24 hours after adding salt | The salt tests fine but the light stays |
| IntelliChlor | No lights | Power center fuse, no power from the timer, wiring | Timer or automation is running the pump | It stays dark with the pump on |
Don't open the equipment or touch gas parts.
What does Lucent's on-site Pentair diagnosis cover?
We look at the whole equipment pad, not just the part showing the alarm, because a pump or filter problem often trips the heater or salt cell. We find what failed, then send you an estimate before any repair.
We diagnose the whole equipment pad, not only the heater, so the fix lasts. After we diagnose it, we send you an estimate and call to walk you through it. The service call fee goes toward the labor for your repair if you go ahead with it within 30 days. If you don't, the service call fee is still due. What a repair costs depends on the part; we price it after diagnosis. If a repair will do the job, we fix the equipment you have. If you'd rather stay with Pentair, we'll supply and install that instead. The choice is always yours, though.
- 25+ Years in the Pool Business
- Lucent Pools is insured.
- Lucent Pools is CPO certified by the Pool & Hot Tub Alliance (PHTA).
More help: pool repair in Fort Worth and Dallas–Fort Worth, pool repair in Keller, pool repair in Southlake.
Need a Repair?
What a repair costs depends on the part; we price it after diagnosis. Call 817-339-6770. Monday through Friday, 8:00 AM to 6:00 PM. Saturday closed. Sunday closed. See all pool repairs.




